7823
SOLUTION: Replace bushings (p/n 25TU78090).
SPECIAL NOTE: Solution provided by Joe Nicolella, Color Specialist, KBT Arlington.
TAUS0618511EN00
Solution ID
0
Solution Usage
Description
Marks on copies.
Solution
CAUSE: Paper dust build up on the oil regulating blade in the fuser unit.
SOLUTION: Clean or replace the oil regulating blade (p/n 25TU54061). The scheduled replacement interval is 120,000 copies.
SPECIAL NOTE: Solution provided by Robert Madsen, Color Specialist, KBT Dallas.
TAUS0619369EN00
Solution ID
0
Solution Usage
Description
Copies are misaligned when using book copy mode.
Solution
CAUSE: Original detection not enabled.
SOLUTION: To enable original detection, perform the following:
1. Access the service mode by pressing the [Utility] key, touching [Meter Count] pressing the [Stop] key,0,0 [Stop] 0,1.
2. Once service mode is accessed, touch [Setting 2] on the touchscreen.
3. On the Setting menu, touch [Orig. Detect Sensor].
4. Touch [Set] to enable original detection.
5. Touch [Ex] three times to return to the Basic screen.
TAUS0621603EN00
Solution ID
0
Solution Usage
Description
Upgrading system software using card reader utility.
Solution
See Tool Bulletin #71a for details.
Note: To view the PDF, Acrobat* Reader must be installed. Acrobat Reader can be downloaded for free from the Adobe* Web site at:
[[http://www.adobe.com/products/acrobat/readstep2.html| URL http://www.adobe.com/products/acrobat/readstep2.html]]
* Trademark ownership information
TAUS0621617EN00
Solution ID
0
Solution Usage
Description
Peripheral and Accessory Reference List.
Solution
See Technical Operations Bulletin #A2 D3 (Peripheral and Accessory Reference List) for details.
Note: To view the PDF, Acrobat* Reader must be installed. Acrobat Reader can be downloaded for free from the Adobe* Web site at:
[[http://www.adobe.com/products/acrobat/readstep2.html| URL http://www.adobe.com/products/acrobat/readstep2.html]]
* Trademark ownership information
TAUS0623453EN00
Solution ID
0
Solution Usage
Description
Equitrac* products such as PrintLog* Professional are unable to correctly track both print and copy volume.
Solution
51
Copyright 2006, Konica Minolta Business Solutions U.S.A., Inc.
October 2006