7823
complains of poor solid fill. At setting of 7% may cause overtoning and toner misting.
h. Press [Ex.] to exit the service mode and return to the normal copy screen.
3. Adjust the ATDC toner supply by performing the following:
a. Enter the service mode by following the above steps a through d.
b. Press [ATDC Toner Supply].
c. Press [Black].
d. Press the Print key. It will turn from green to amber. When it turns green again, the adjustment is complete.
e. Press [Ex.] to exit the service mode and return to the normal print screen.
TAUS0608367EN00
Solution ID
4
Solution Usage
Description
Unable to select more than two copies when duplexing.
Solution
This is a product limitation of the 7823 due to the stackless duplex operation and two 8.5x11 images per drum rotation. The image is purged from memory
after each side is printed.
TAUS0608752EN00
Solution ID
4
Solution Usage
Description
C0200 is displayed during initialization.
Solution
CAUSE: The PC drum charge corona unit is not seated.
SOLUTION: Remove and inspect the PC drum charge corona unit, properly reinstall and confirm operation. Replace the PC drum charge corona unit as
necessary (p/n 11UM-2510).
TAUS0608803EN00
Solution ID
4
Solution Usage
Description
Editor board, can the editor board option be used with a print controller?
Solution
The Editor Board can only be used with an external print controller only. The Editor board and the Fiery X2e* internal print controller use the same slot in the
7823, therefore, they can't both be used.
* Trademark ownership information
TAUS0609078EN00
Solution ID
4
Solution Usage
Description
Fiery* X2e, when scanning, the image taken-in to the PC is partially or totally blank.
Solution
CAUSE: When the machine is scanning, noise can occur on the signal line between the video interface and the X2e controller board.
SOLUTION: There is a software patch (515559.exe) available form the konica FTP site that corrects this issue. See 7823 technical Bulletin #2 for more
information .
FTP site [[Internal Link for Faxing/Printing FTP site information| RUN V:\text\Wordpad.exe v:\text\CBC009.txt]] FTP_ user site.txt file [[Internal Link for
Faxing/Printing FTP_ user site.txt file information| RUN V:\text\Wordpad.exe v:\text\CBC010.txt]]
* Trademark ownership information
TAUS0610164EN00
Solution ID
4
Solution Usage
Description
How to clear The Toner Collection Bottle Is Full message.